Тип публикации: статья из журнала
Год издания: 2021
Ключевые слова: cr, er, implant, implantoplasty method, peri-implantitis, titanium brush, ysgg 2780nm laser
Аннотация: The aim of the study was to compare the effectiveness of decontamination of various types of implant surfaces removed due to the diagnosis of peri-implantitis using implantoplasty, titanium brush and Er;Cr;YSGG 2780nm laser. We studied 30 dental implants,
Издание
Журнал: Journal of International Dental and Medical Research
Выпуск журнала: Vol. 14, Is. 3
Номера страниц: 910-918
ISSN журнала: 1309100X
Издатель: University of Dicle
Персоны
- Furtsev T.V. (Federal State Budgetary Educational Institution of Higher Education, ''Krasnoyarsk State Medical University named after professor Voino-Yasenetsky V.F.'', Partizana Zheleznyaka St,1, Krasnoyarsk, Russian Federation, Medi Dent Ltd, Molokova )
- Zeer G.M. (Federal State Autonomous Educational Institution of Higher Education, ''Siberian Federal University", prospect Svobodny,79, Krasnoyarsk, Russian Federation)
- Zelenkova E.G. (Federal State Autonomous Educational Institution of Higher Education, ''Siberian Federal University", prospect Svobodny,79, Krasnoyarsk, Russian Federation)