Diagnosis of corneal pathology by laser fluorescence spectroscopy | Научно-инновационный портал СФУ

Diagnosis of corneal pathology by laser fluorescence spectroscopy

Тип публикации: статья из журнала

Год издания: 2012

Идентификатор DOI: 10.1007/s10812-012-9649-4

Ключевые слова: laser fluorescence spectroscopy of the cornea, contact lenses

Аннотация: We have studied the difference between the fluorescence spectra of the human cornea in vivo under normal conditions and after contact lenses have been worn for different lengths of time, with excitation by emission from a nitrogen laser (337 nm). The most significant sections of the difference spectrum were identified, corresponding to peaks for endogenous fluorophores (NADH and collagen). A high correlation was found between how long the contact lenses have been worn and the fluorescence intensity ratio for wavelengths 460 nm and 410 nm.

Ссылки на полный текст

Издание

Журнал: JOURNAL OF APPLIED SPECTROSCOPY

Выпуск журнала: Vol. 79, Is. 4

Номера страниц: 626-631

ISSN журнала: 00219037

Место издания: NEW YORK

Издатель: SPRINGER

Персоны

  • Salmin V.V. (Siberian Federal University)
  • Vladimirova E.S. (Siberian Federal University)
  • Lazarenko V.I. (V. F. Voino-Yasenetsky Krasnoyarsk State Medical University)
  • Salmina A.B. (V. F. Voino-Yasenetsky Krasnoyarsk State Medical University)
  • Hovalyg M.S. (V. F. Voino-Yasenetsky Krasnoyarsk State Medical University)

Информация о публикациях загружается с сайта службы поддержки публикационной активности СФУ. Сообщите, если заметили неточности.